Send Message
Home ProductsELCB Circuit Breaker

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

Certification
China WENZHOU SANTUO ELECTRICAL CO.,LTD. certification
China WENZHOU SANTUO ELECTRICAL CO.,LTD. certification
I'm Online Chat Now

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

2Pole 4 Pole differential current  Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker
2Pole 4 Pole differential current  Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker
2Pole 4 Pole differential current  Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker 2Pole 4 Pole differential current  Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

Large Image :  2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

Product Details:
Place of Origin: China
Brand Name: SONTUNE
Certification: CE
Model Number: STG
Payment & Shipping Terms:
Minimum Order Quantity: 500pcs
Price: Negotiable
Supply Ability: 2000pcs/day

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

Description
Standard: IEC60947-2 Coil Voltage: 230/400V
In: 5~15A(5,10,15)A;10~30A(10,15,20,25,30,)A;30~60A(30,45,60)A I△n: 300,500(mA)
Install: Fixed Color: White
High Light:

earth leakage breaker

,

electric leakage circuit breaker

STG(Pg)Series 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

 

GENERAL


An Earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use Residual Current Circuit Breakers which instead detect leakage current directly.

 

Specification:

 

Type STG230 STG420
Rated Current(A) 10A,15A,20A,25A,32A,40A,50A,60A 10A,15A,20A,25A,32A,40A,50A,60A
Pole Number 2Pole 4Pole
Leakage acting current(mA) 300mA,500mA 300mA ,500mA
Range of break-off 0.5~1.0X IΔn 0.5~1.0X IΔn
Rated Voltage(V) 220V-250VAC 240V/415VAC
Tripping time 100ms 100mS
Life 100000 times 100000 times
Ambient Temperature -5°C ~ +55 °C -5°C ~ +55 °C

 

Voltage-operated (ELCB)

 

Voltage ELCBs have been in widespread use since then, and many are still in operation but are no longer installed in new construction. A voltage-operated ELCB detects a rise in potential between the protected interconnected metalwork (equipment frames, conduits, enclosures) and a distant isolated Earth reference electrode. They operate at a detected potential of around 50 volts to open a main breaker and isolate the supply from the protected premises.

 

A voltage-operated ELCB has a second terminal for connecting to the remote reference Earth connection.

 

The Earth circuit is modified when an ELCB is used; the connection to the Earth rod is passed through the ELCB by connecting to its two Earth terminals. One terminal goes to the installation Earth CPC (circuit protective conductor, aka Earth wire), and the other to the Earth rod (or sometimes other type of Earth connection).