Product Details:
|
Standard: | IEC 60947-1 | Frequency: | 50Hz,60Hz,50Hz/60Hz |
---|---|---|---|
Pole: | 3P, 4P | Texture: | PA66 |
Credential: | CE | Color: | White And Black |
Highlight: | alternating current contactor,motor starter contactor |
Flame Retardant 3 Pole Ac Contactor STC-N40A PA66 QA Copper Wire
GENERAL
STC-N Series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-1.
Standard: IEC60947-1;
Coil Voltage: 24,48,110,220,230,240,380,415,440V
Rated Current:9,12,18,25,32,40,50,65,75,85A
Pole:3P, 4P
Model
|
MC-9
|
MC-12
|
MC-18
|
MC-22
|
MC-32
|
MC-40
|
||
IEC-60947 AC1 duty |
20A
|
20A
|
25A
|
32A
|
50A
|
60A
|
||
UL AC3 duty | 200-240V |
2.5KW 11A
|
3.5KW 13A
|
4.5KW 18A
|
5.5KW 22A
|
7.5KW 32A
|
11KW 40A
|
|
380-440V |
4KW 9A
|
5.5KW 12A
|
7.5KW 18A
|
11KW 22A
|
15KW 32A
|
18.5KW 40A
|
||
500-550V |
4KW 7A
|
7.5KW 12A
|
7.5KW 13A
|
15KW 22A
|
18.5KW 28A
|
22KW 32A
|
||
690V |
4KW 5A
|
7.5KW 9A
|
7.5KW 9A
|
15KW 18A
|
18.5KW 21A
|
22KW 25A
|
||
Continuous current(th) |
20A
|
25A
|
30A
|
32A
|
45A
|
50A
|
||
AC Motor | 1P | 115V |
0.5HP
|
0.5HP
|
1HP
|
2HP
|
2HP
|
3HP
|
230V |
1HP
|
2HP
|
3HP
|
3HP
|
5HP
|
5HP
|
||
3P | 200V |
2HP
|
3HP
|
5HP
|
7HP
|
7.5HP
|
10HP
|
|
230V |
2HP
|
3HP
|
5HP
|
7.5HP
|
10HP
|
10HP
|
||
460V |
5HP
|
7.5HP
|
10HP
|
10HP
|
20HP
|
25HP
|
||
575V |
7.5HP
|
10HP
|
15HP
|
15HP
|
20HP
|
25HP
|
||
Panel installation |
Rail & screw
|
|||||||
External dimension(mm) |
44x80x86.8
|
68x82x94.6
|
||||||
Mounting dimension(mm) | 30~35x48~59 35x60 |
Contactors come in many forms with varying capacities and features. Unlike a circuit breaker, a contactor is not intended to interrupt a short circuit current. Contactors range from those having a breaking current of several amperes to thousands of amperes and 24 V DC to many kilovolts. The physical size of contactors ranges from a device small enough to pick up with one hand, to large devices approximately a meter (yard) on a side.
Contactors are used to control electric motors, lighting, heating, capacitor banks, thermal evaporators, and other electrical loads.
Contact Person: Mr. Sunny Zhang
Tel: 86-13868610160