Product Details:
|
Standard: | IEC 60947-2,GB14048.2 | Coil Voltage: | AC400( 380 ) |
---|---|---|---|
In: | 63,80,100,125,160,200,250,350A | Pole: | 3P,4P |
Install: | Fixed | Texture: | Plastic |
Highlight: | moulded circuit breaker,motor protection circuit breaker |
Stn2 3p4p Moulded Case Circuit Breaker
Molded case circuit breakers can have very high current ratings, which allows them to be used in heavy duty applications. The following are some typical uses of an MCCB:
In summary, an MCCB offers adequate protection whenever an application requires a high current rating, adjustable trip settings, or a combination of both factors.
Rated current of release(A) |
Thermodynamic release (ambient temp +40°C) |
operational current of magnetic ralease(A) |
|||
1.05In(cold state) in operative time(h) |
1.30(heat state) inoperative time(h) |
||||
In≤63 | ≥1 | <1 | 10In±20% | ||
63 | ≥2 | <2 | 10In±20% | ||
100 | ≥3 | <3 | 5-10In±20% | ||
Rated current of release(A) |
Thermodynamic release (ambient temp +40°C) |
operational current of magnetic ralease(A) |
|||
1.0 In(cold state) operative time(h) |
1.20(heat state) operative time(h) |
1.50(heat state) operative time(h) |
1.01(heat state) operative time(h) |
||
12.5 | ≥2 | <2 | ≤4min | 2s | 12In±20% |
Note
1. The N-pole breaker has no protection which closing and opening with the other three poles. 2. The type of thermal magnetic for NS-400/630 has no four poles.
1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10A,10 and 20
2. Short-circuit protection with adjustable threshold (6...13xIr)
3. Phase failure protection (built-in electronic release: operates unbalanced single-phase currentat 40% and more than )(tripping time delay 4s±10%),as defined by IEC60947-4.1
4. Load indication : Flashing more than Ir setting threshold
5. Fault indication
LEDs indicates the type of fault that caused tripping
Overload (LT protection) or abnormal component temperature (>Ir);
Short-circuit (ST or instantaneous protection)( >Im);
Phase failure (right LED);
Microprocessor malfunction ( (>Ir) ( >Im) and phase failure LEDs all go on )
Battery powered. Spare battery are supplied in an adapter box. When a fault occurs ,the LED indicating the type of fault ,lights for about 10 minutes . The information is however stored inmemory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset .