Product Details:
|
Standard: | IEC 61008-1 | Install: | Din Rail |
---|---|---|---|
Ue: | 230V | Type: | RCCB |
Beaking Capacity: | 3KA,6KA | NAME: | Mini Circuit Breaker |
High Light: | residual current circuit breaker rccb,residual current circuit breaker |
2P 4P Electronic (Magnetic)Type Residual Current Circuit Breaker STEZC-63L series is in conformity with the standards of IEC61008.It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunkline.Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.It can be used in circuits up to single phase 230V,three phase 400V,50 or 60Hz.
Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
And It complies with standard of IEC/EN61008.1
Product Over View:
1. Provide protection against earth fault/leakage current and function of isolation
2. High short-circuit current withstand capacity
3. Applicable to terminal and pin/fork type busbar connection
4. Equipped with finger protected connection terminals
5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity
6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Specifications
Model | Electronic type / magnetic type |
Residual Current characteristics | A, AC |
Pole NO | 2P/4P |
Rated Current (A) | 10A,16A,20A,25A,32A,40A,63A |
Rated Voltage (V) | 230/ 400V |
Rated Residual operating current | 30 ma , 100ma ,300ma ,500ma |
Rated conditional resdual short circuit current | 6KA |
Electro-machanical endurance | over 4000 cycles |
Our Services: |
1. Competitive price |
2. Continuance Service and support |
3. Good-after service |
4. Quality Reliability and Long Product Life. |
Contact Person: Mr. Sunny Zhang
Tel: 86-13868610160
Fax: 86-577-67235072