Product Details:
|
Standard: | IEC 61008-1 | Pole: | 2P,4P |
---|---|---|---|
Rate Voltage: | 230/400V | Type: | RCCB |
Transport Package:: | Inner Box/Carton | In: | 16,20,25,32,40,63A |
High Light: | residual current circuit breaker rccb,residual current circuit breaker |
a Professional Factory 4p 230V RCCB Circuit Breaker
Application
L-DX is applicable to a line of AC 50Hz/60Hz, rated voltage 230V for single pole twowire, 2-pole or 400V for 4-pole, It can protect the line and motor from overload and short circuit. It can also be used for infrequent line conversion and infrequent motor start. It conforms with the standards of IEC61008.
Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
1. Provide protection against earth fault/leakage current and function of isolation
2. High short-circuit current withstand capacity
3. Applicable to terminal and pin/fork type busbar connection
4. Equipped with finger protected connection terminals
5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity
6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Specifications
Model | Electronic type / magnetic type |
Residual Current characteristics | A, AC |
Pole NO | 2P/4P |
Rated Current (A) | 10A,16A,20A,25A,32A,40A,63A |
Rated Voltage (V) | 230/ 400V |
Rated Residual operating current | 30 ma , 100ma ,300ma ,500ma |
Rated conditional resdual short circuit current | 6KA |
Electro-machanical endurance | over 4000 cycles |
Protection Characteristic
• Overload & Short Circuit Protection
• Residual Current Protection
Hightlights
• CE 61008-1
• Thick Contact Points, long life, safe and reliable
• High quality fireproof plastic
• Pure Copper Coil
• Self-Design PCB board, easy to control quality, best PCB in the market
Contact Person: Mr. Sunny Zhang
Tel: 86-13868610160
Fax: 86-577-67235072