Product Details:
|
Structure: | Combination | Signal: | Discrete |
---|---|---|---|
Rated Current: | 09,12,18,25,32,40,50,65,80,95A | Frequency: | 50Hz/60Hz |
Color: | White | Install: | Screw Fixation |
High Light: | magnetic motor starter,dol starter |
Magnetic Starter Se1-N Series ( LE1-N ) From 9-95A for Motor Protection
GENERAL
SE1-N series Magnetic starteris mainly applied to circuit of AC 50 or 60Hz,voltage up to 550Vfor far distance making and breaking circuit and frequently starting and controlling motor. It hasthe features of small volume, light weight, low power consumption, high efficiency, safe and reliable performance.
Implementation
A magnetic starter has a contactor and an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor.Overload relays may rely on heat produced by the motor current to operate a bimetal contact or release a contact held closed by a low-melting-point alloy.[citation needed] The overload relay opens a set of contacts that are wired in series with the supply to the contactor feeding the motor. The characteristics of the heaters can be matched to the motor so that the motor is protected against overload. Recently, microprocessor-controlled motor digital protective relays offer more comprehensive protection of motors.
Specifications
Maximum power AC3 duty(KW) | Rated current(A) | Type of enclosure | Code number | Suitable thermal relay(A) | ||||||
220V 230V | 380V 400V | 415V | 440V | 500V | 660V 690 | LL (long life) | NL(3) (normal life) | |||
2.2 | 4 | 4 | 4 | 5.5 | 5.5 | 9 | IP42 IP65 |
SE1-N094.. SE1-N093.. |
- - |
TR2-D1312 TR2-D1314 |
3 | 5.5 | 5.5 | 5.5 | 7.5 | 7.5 | 12 | IP42 IP55 |
SE1-N124.. SE1-N123.. |
SE1-N094.. SE1-N093.. |
TR2-D1316 |
4 | 7.5 | 9 | 9 | 10 | 10 | 18 | IP42 IP55 |
SE1-N188.. SE1-N185.. |
SE1-N124.. SE1-N123.. |
TR2-D1321 |
5.5 | 11 | 11 | 11 | 5 | 15 | 25 | IP42 IP55 |
SE1-N258.. SE1-N255.. |
SE1-N188.. SE1-N185.. |
TR2-D1322 TR2-D2353 |
7.5 | 15 | 15 | 15 | 18.5 | 18.5 | 32 | IP55 | SE1-N325.. | SE1-N255.. | TR2-D2355 |
11 | 18.5 | 22 | 22 | 22 | 30 | 40 | IP55 | SE1-N405.. | SE1-N325.. | TR2-D3353 TR2-D3355 |
15 | 22 | 25 | 30 | 30 | 33 | 50 | IP55 | SE1-N505.. | SE1-N405.. | TR2-D3357 TR2-D3359 |
18.5 | 30 | 37 | 37 | 37 | 37 | 65 | IP55 | SE1-N655.. | SE1-N505.. | TR2-D3361 |
22 | 37 | 45 | 45 | 55 | 45 | 80 | IP55 | SE1-N805.. | SE1-N655.. | TR2-D3363 TR2-D3365 |
25 | 45 | 45 | 45 | 55 | 45 | 95 | IP55 | SE1-N955.. | SE1-N805.. | TR2-D3365 |
Contact Person: Mr. Sunny Zhang
Tel: 86-13868610160
Fax: 86-577-67235072