10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker

Certification
China WENZHOU SANTUO ELECTRICAL CO.,LTD. certification
China WENZHOU SANTUO ELECTRICAL CO.,LTD. certification
I'm Online Chat Now

10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker

10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker
10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker

Large Image :  10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker

Product Details:
Place of Origin: China
Brand Name: SONTUNE
Certification: CE
Model Number: ST61
Payment & Shipping Terms:
Minimum Order Quantity: 10000PCS
Price: Negotiable
Packaging Details: 240PCS/CTN
Delivery Time: 15DAYS
Supply Ability: 5000PCS/DAY

10KA MCB Circuit Breaker Tripping Curve , IEC 60898 Type B Circuit Breaker

Description
Type: MCB Breaking Capacity: 10kA
Standard: IEC 60898 Ue: 230/400V
In: 1,2,4,6,10,16,20,25,32,40,50,63A Pole: 1p,2p,3p,4p
High Light:

miniature circuit breaker

,

automotive circuit breaker

St61 Series ( MCB ) 1p 2p 3p 4p Miniature Circuit Breaker

 

 

GENERAL


ST61 series high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V

3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.

 

1. Application:For protecting cables and equipments against overload and short circuit.

2. General rules for choosing MCB.

  1. Technical data of the network at the point considered

The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

  1. There are 3 curvve characteristics for magnetic operation:

B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.

D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)

 



 

Specification:

 

Model ST61 MCB
Pole 1P,2P,3P,4P
Rated Current(In) 1,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage(Un) 230/400V
Rated Frequency 50/60HZ
Tripping curve B,C,D
Magnetic releases B curve: between 3and 5 In
C curve: between 5and 10In
D curve: between 10 and 14In
Electro-mechanical endurance over 6000 cycles

 

 

  Standard   IEC/EN 60898-1
Electrical
features
Rated current In A 1,2,4,6,10,16,20,25,32,40,50,63
Poles P 1,2,3,4
Rated voltage Ue V 230/400
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity A 6000,10000
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1 min Kv 2
Pollution degree   2
Thermo-magnetic release characteristic   B,C,D
Mechanical
features
Electrical life t 4000
Mechanical life t 10000
Protection degree   IP20
Reference temperature for setting
of thermal element
30
Ambient temperature
(with daily average ≤35℃)
-5~+40(Special application please refer to
temperature compensation correction)
Storage temperature -25~+70
Installation Terminal connection type   Cable/Pin-type busbar
Terminal size top/bottom for cable mm2 25
AWG 18-3
Therminal size top/bottom for busbar mm2 25
AWG 18-3
Tightening torque N*m 2
In-lbs 18
Mounting   on DIN rail EN 60715(35mm)by means of fast clip device
Connection   From top and bottom

 

 