Product Details:
|
Ue: | 230/400V | Standard: | IEC61009 |
---|---|---|---|
Breaking Capacity: | 3KA,4.5KA,6KA | Type: | RCBO |
Credential: | CE,CB,SAA, ISO9001 | Color: | PA66 |
Highlight: | miniature circuit breaker,miniature current circuit breaker |
RCBO 50 / 60hz Type A Model Residual Circuit Breaker With Over Current Protection
STRO7-63 series high breaking capacity Residual current Circuit Breaker with over current protection is used in AC50/60Hz, rated voltage of 230V
2, 4 poles 400V, rated current to 63A for overload and short-circuit protection and Leakage current protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC61009 standard.
General
Application:For protecting cables and equipments against overload and short circuit. General rules for choosing RCBO .
Technical data of the network at the point considered
The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.
Model | A RCBO (electrical type, magnetic type) |
Standard | IEC61009 |
Pole | 2P, 4P |
Rated Short-circuit capacity(Icn) | 3KA,4.5KA,6KA |
Rated Current(In) | 16,20,25,32,40,50,63A |
Rated Voltage(Un) | AC230(240)/400(415)V |
Rated Frequency | 50/60HZ |
Tripping curve | B,C,D |
Magnetic releases | B curve: between 3and 5 In |
C curve: between 5and 10In | |
D curve: between 10 and 14In | |
Electro-mechanical endurance | over 6000 cycles |
Standard | IEC/EN 61009 | ||
Electrical features |
Rated current In | A | 16,20,25,32,40,50,63 |
Poles | P | 2, 4 | |
Rated voltage Ue | V | AC 240/415 | |
Insulation voltage Ui | V | 500 | |
Rated frequency | Hz | 50/60 | |
Rated breaking capacity | A | 4500 ;6000 | |
Rated impulse withstand voltage(1.2/50)Uimp | V | 4000 | |
Dielectric test voltage at ind.Freq.for 1 min | Kv | 2 | |
Pollution degree | 2 | ||
Thermo-magnetic release characteristic | B,C,D | ||
Mechanical features |
Electrical life | t | 4000 |
Mechanical life | t | 10000 | |
Protection degree | IP20 | ||
Reference temperature for setting of thermal element |
℃ | 30 | |
Ambient temperature (with daily average ≤35℃) |
℃ | -5~+40(Special application please refer to temperature compensation correction) |
|
Storage temperature | ℃ | -25~+70 | |
Installation | Terminal connection type | Cable/Pin-type busbar | |
Terminal size top/bottom for cable | mm2 | 25 | |
AWG | 18-3 | ||
Therminal size top/bottom for busbar | mm2 | 25 | |
AWG | 18-3 | ||
Tightening torque | N*m | 2 | |
In-lbs | 18 | ||
Mounting | on DIN rail EN 60715(35mm)by means of fast clip device | ||
Connection | From top and bottom |
Discount and promotion price is available.
Technology support is available.
Contact Person: Mr. Sunny Zhang
Tel: 86-13868610160
Fax: 86-577-67235072